{"users":[{"id":1,"username":"lucy.sierracircuits","name":"Lucy Iantosca","avatar_template":"/user_avatar/sierraconnect.protoexpress.com/lucy.sierracircuits/{size}/8_2.png","admin":true,"moderator":true,"trust_level":4},{"id":58,"username":"Mohamed_Faheemuddin","name":"Mohamed","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/m/4da419/{size}.png","trust_level":2},{"id":2402,"username":"vanoopraja","name":"ANOOP","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/v/e99b99/{size}.png","trust_level":0},{"id":59,"username":"timothy.phillips","name":"Tim","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/t/d78d45/{size}.png","trust_level":3},{"id":526,"username":"JimJJewett","name":"Jim","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/j/d78d45/{size}.png","trust_level":3},{"id":53,"username":"PoulomiG","name":"Poulomi","avatar_template":"/user_avatar/sierraconnect.protoexpress.com/poulomig/{size}/288_2.png","trust_level":2},{"id":48,"username":"atar.mittal","name":"Atar Mittal","avatar_template":"/user_avatar/sierraconnect.protoexpress.com/atar.mittal/{size}/49_2.png","moderator":true,"trust_level":4},{"id":500,"username":"will","name":"William","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/w/90ced4/{size}.png","trust_level":2},{"id":495,"username":"jerrysaitter","name":"Jerry","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/j/c68b51/{size}.png","trust_level":2},{"id":504,"username":"Timmann17","name":"Tim","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/t/d07c76/{size}.png","trust_level":2},{"id":499,"username":"Lieniner","name":"David","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/l/e99b99/{size}.png","trust_level":2},{"id":6,"username":"milan","name":"Milan Y","avatar_template":"/user_avatar/sierraconnect.protoexpress.com/milan/{size}/10_2.png","trust_level":2},{"id":2106,"username":"s1109409","name":"Francesco","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/s/8edcca/{size}.png","trust_level":0},{"id":315,"username":"Pranav","name":"Pranav","avatar_template":"/user_avatar/sierraconnect.protoexpress.com/pranav/{size}/425_2.png","trust_level":4},{"id":2051,"username":"ykb","name":"Yakub","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/y/898d66/{size}.png","trust_level":0},{"id":13,"username":"abhishek","name":"Abhishek Chari","avatar_template":"/user_avatar/sierraconnect.protoexpress.com/abhishek/{size}/45_2.png","trust_level":4},{"id":1769,"username":"rayansayedpd","name":"rayan","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/r/82dd89/{size}.png","trust_level":1},{"id":1806,"username":"marko.duksi","name":"Marko","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/m/7ea924/{size}.png","trust_level":2},{"id":603,"username":"jonathan.lloyd.riley","name":"Jonathan","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/j/3bc359/{size}.png","trust_level":3},{"id":47,"username":"Pooja_Mitra","name":"Pooja Mitra","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/p/ce73a5/{size}.png","trust_level":2},{"id":505,"username":"BerndKruger","name":"Bernd","avatar_template":"https://avatars.discourse-cdn.com/v4/letter/b/a5b964/{size}.png","trust_level":2}],"primary_groups":[],"flair_groups":[],"topic_list":{"can_create_topic":false,"filter":"latest","more_topics_url":"/c/signal-and-power/17?page=1","per_page":30,"top_tags":[{"id":75,"name":"signal-integrity","slug":"signal-integrity"},{"id":5,"name":"emc","slug":"emc"},{"id":45,"name":"emi","slug":"emi"},{"id":20,"name":"controlled-impedance","slug":"controlled-impedance"},{"id":7,"name":"high-speed","slug":"high-speed"},{"id":132,"name":"impedance","slug":"impedance"},{"id":47,"name":"power-integrity","slug":"power-integrity"},{"id":199,"name":"trace-talks","slug":"trace-talks"},{"id":40,"name":"via","slug":"via"},{"id":18,"name":"decoupling-capacitor","slug":"decoupling-capacitor"},{"id":11,"name":"hdi","slug":"hdi"},{"id":211,"name":"karen-burnham","slug":"karen-burnham"},{"id":76,"name":"propagation-delay","slug":"propagation-delay"},{"id":90,"name":"eric-bogatin","slug":"eric-bogatin"},{"id":236,"name":"eye-diagram","slug":"eye-diagram"},{"id":231,"name":"grounding","slug":"grounding"},{"id":186,"name":"high-current","slug":"high-current"},{"id":227,"name":"jitter-in-pcbs","slug":"jitter-in-pcbs"},{"id":184,"name":"microwave-pcb-design","slug":"microwave-pcb-design"},{"id":241,"name":"pcb-transmisison-lin","slug":"pcb-transmisison-lin"},{"id":46,"name":"pi","slug":"pi"},{"id":242,"name":"podcast","slug":"podcast"},{"id":191,"name":"radio-frequency-pcb","slug":"radio-frequency-pcb"},{"id":158,"name":"rf-pcb-materials","slug":"rf-pcb-materials"},{"id":190,"name":"rf-via-design","slug":"rf-via-design"},{"id":100,"name":"rick-hartley","slug":"rick-hartley"},{"id":2,"name":"routing","slug":"routing"},{"id":160,"name":"shielding","slug":"shielding"},{"id":101,"name":"si","slug":"si"},{"id":237,"name":"signal-integrity-ana","slug":"signal-integrity-ana"},{"id":139,"name":"signal-reflection","slug":"signal-reflection"}],"topics":[{"fancy_title":"About the Signal and Power category","id":25,"title":"About the Signal and Power category","slug":"about-the-signal-and-power-category","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2023-09-05T22:20:40.277Z","last_posted_at":null,"bumped":true,"bumped_at":"2023-09-27T18:12:21.527Z","archetype":"regular","unseen":false,"pinned":true,"unpinned":null,"excerpt":"This category is for users who seek help or wish to share their experience with PCB signal and power. \nOur subcategories are: \n\nImpedance\nSignal integrity\nPower integrity\nHigh speed and frequency\nEMC and EMI\n\nTag @Sierra&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[],"tags_descriptions":{},"views":371,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":17,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Typical Signal Integrity Issues PCB Designers Should Watch Out For","id":4378,"title":"Typical Signal Integrity Issues PCB Designers Should Watch Out For","slug":"typical-signal-integrity-issues-pcb-designers-should-watch-out-for","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/1130a73b7b7c433ee57e137c6daf327b224fa75f_2_847x1024.jpeg","created_at":"2026-08-17T13:41:07.065Z","last_posted_at":"2026-08-17T13:41:07.216Z","bumped":true,"bumped_at":"2026-08-17T13:41:07.216Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"As signal rise times become faster and data rates increase, PCB traces can no longer be treated as simple electrical connections. Trace impedance, return current paths, coupling between adjacent conductors, and power &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":75,"name":"signal-integrity","slug":"signal-integrity"}],"tags_descriptions":{},"views":33,"like_count":1,"has_summary":false,"last_poster_username":"Mohamed_Faheemuddin","category_id":19,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":58,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"What is Signal Propagation Delay in PCBs?","id":3836,"title":"What is Signal Propagation Delay in PCBs?","slug":"what-is-signal-propagation-delay-in-pcbs","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2026-01-30T05:05:47.669Z","last_posted_at":"2026-01-30T05:05:47.749Z","bumped":true,"bumped_at":"2026-01-30T05:05:47.749Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Originally published at:\t\t\thttps://www.protoexpress.com/blog/signal-propagation-delay-pcb/ \n Delay is frustrating, whether in our daily lives or the devices we use for our convenience. Propagation delay/time delay inhibi&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":76,"name":"propagation-delay","slug":"propagation-delay"}],"tags_descriptions":{},"views":38,"like_count":0,"has_summary":false,"last_poster_username":"Mohamed_Faheemuddin","category_id":19,"op_like_count":0,"pinned_globally":false,"featured_link":"https://www.protoexpress.com/blog/signal-propagation-delay-pcb/","featured_link_root_domain":"protoexpress.com","has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":58,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Clarification on PCB Routing, EMI and 6 kV Surge Performance – Isolated DC-DC Input Stage","id":3799,"title":"Clarification on PCB Routing, EMI and 6 kV Surge Performance – Isolated DC-DC Input Stage","slug":"clarification-on-pcb-routing-emi-and-6-kv-surge-performance-isolated-dc-dc-input-stage","posts_count":2,"reply_count":0,"highest_post_number":2,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/f723134b974d81b3ff4b2381cc7428c14f67c7a7_2_1024x522.png","created_at":"2026-01-13T17:49:19.484Z","last_posted_at":"2026-01-13T18:28:14.299Z","bumped":true,"bumped_at":"2026-01-13T18:28:14.299Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Dear Team, \nWe have designed an isolated –48 V DC-DC power input stage and would like your guidance on the PCB routing approach with respect to EMI performance and surge immunity. \nSystem Overview \n\n\nInput supply: –48 V &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[],"tags_descriptions":{},"views":56,"like_count":1,"has_summary":false,"last_poster_username":"timothy.phillips","category_id":22,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":2402,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":59,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"7 Tips and PCB Design Guidelines for EMI and EMC","id":3780,"title":"7 Tips and PCB Design Guidelines for EMI and EMC","slug":"7-tips-and-pcb-design-guidelines-for-emi-and-emc","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2026-01-06T08:58:55.702Z","last_posted_at":"2026-01-06T08:58:55.778Z","bumped":true,"bumped_at":"2026-01-06T08:58:55.778Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Originally published at:\t\t\thttps://www.protoexpress.com/blog/7-pcb-design-tips-solve-emi-emc-issues/ \n Electromagnetic interference (EMI) is associated with every electronic device we use nowadays. If you turn on your ra&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":45,"name":"emi","slug":"emi"},{"id":5,"name":"emc","slug":"emc"}],"tags_descriptions":{},"views":33,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":19,"op_like_count":0,"pinned_globally":false,"featured_link":"https://www.protoexpress.com/blog/7-pcb-design-tips-solve-emi-emc-issues/","featured_link_root_domain":"protoexpress.com","has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"5 impedance discontinuity triggers in RF PCBs","id":3430,"title":"5 impedance discontinuity triggers in RF PCBs","slug":"5-impedance-discontinuity-triggers-in-rf-pcbs","posts_count":3,"reply_count":1,"highest_post_number":3,"image_url":null,"created_at":"2025-08-05T18:26:06.046Z","last_posted_at":"2025-08-12T13:25:52.403Z","bumped":true,"bumped_at":"2025-08-12T13:25:52.403Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Impedance discontinuities can sneak up on you. \nWatch out for layout trouble spots like: \n\nTrace-to-via transitions\nComponent pads and connector pins\nAntenna feed junctions\n\nTips to minimize reflections: \n• Keep trace&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":20,"name":"controlled-impedance","slug":"controlled-impedance"},{"id":132,"name":"impedance","slug":"impedance"}],"tags_descriptions":{},"views":125,"like_count":3,"has_summary":false,"last_poster_username":"PoulomiG","category_id":18,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":1,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Recent Poster","user_id":526,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":53,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"The 4 problems that degrade your high-speed serial links by Prof. Eric Bogatin","id":3382,"title":"The 4 problems that degrade your high-speed serial links by Prof. Eric Bogatin","slug":"the-4-problems-that-degrade-your-high-speed-serial-links-by-prof-eric-bogatin","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-07-22T15:37:46.398Z","last_posted_at":"2025-07-22T15:37:46.476Z","bumped":true,"bumped_at":"2025-07-22T15:37:46.476Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Why does your clean transmitter eye diagram turn into a scrambled mess by the time it reaches the receiver? \nIn this webinar highlight, Prof. Eric Bogatin breaks down the four deterministic problems that sabotage high&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":75,"name":"signal-integrity","slug":"signal-integrity"},{"id":7,"name":"high-speed","slug":"high-speed"}],"tags_descriptions":{},"views":67,"like_count":1,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":21,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"“All the EMC problems really start at the PCB level”","id":3346,"title":"“All the EMC problems really start at the PCB level”","slug":"all-the-emc-problems-really-start-at-the-pcb-level","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/0c8615820dec3cf8de7614b1c7b700618cedea49_2_1024x568.jpeg","created_at":"2025-07-10T15:50:54.226Z","last_posted_at":"2025-07-10T15:50:54.307Z","bumped":true,"bumped_at":"2025-07-10T15:50:54.307Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"&quot;All the EMC problems really start at the PCB level. And then they can manifest at every level above that. Sometimes on the board, sometimes not until you’re looking at an entirely fully assembled electric vehicle city&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":5,"name":"emc","slug":"emc"}],"tags_descriptions":{},"views":56,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":22,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"How do you ensure accurate controlled impedance?","id":3330,"title":"How do you ensure accurate controlled impedance?","slug":"how-do-you-ensure-accurate-controlled-impedance","posts_count":7,"reply_count":0,"highest_post_number":7,"image_url":null,"created_at":"2025-07-02T16:05:51.366Z","last_posted_at":"2025-07-09T16:01:08.403Z","bumped":true,"bumped_at":"2025-07-09T16:01:08.403Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Among the high-speed designs we’ve received lately, we see that getting controlled impedance right on the first try is still tricky. Between variations in actual Dk, copper roughness and stack-up tolerances, things drift&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":20,"name":"controlled-impedance","slug":"controlled-impedance"},{"id":132,"name":"impedance","slug":"impedance"}],"tags_descriptions":{},"views":234,"like_count":4,"has_summary":false,"last_poster_username":"Lieniner","category_id":18,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":48,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Frequent Poster","user_id":500,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Frequent Poster","user_id":495,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Recent Poster","user_id":504,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":499,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"How to Determine the Impedance of a Circuit","id":1013,"title":"How to Determine the Impedance of a Circuit","slug":"how-to-determine-the-impedance-of-a-circuit","posts_count":4,"reply_count":2,"highest_post_number":5,"image_url":null,"created_at":"2024-02-06T15:46:21.105Z","last_posted_at":"2025-07-03T06:47:21.123Z","bumped":true,"bumped_at":"2025-07-03T06:47:21.123Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Originally published at:\t\t\thttps://www.protoexpress.com/blog/how-to-determine-impedance-circuit/ \n Impedance impacts how signals propagate through the board, how power is exchanged between components, and how signals lea&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[],"tags_descriptions":{},"views":274,"like_count":3,"has_summary":false,"last_poster_username":"Pranav","category_id":18,"op_like_count":0,"pinned_globally":false,"featured_link":"https://www.protoexpress.com/blog/how-to-determine-impedance-circuit/","featured_link_root_domain":"protoexpress.com","has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":6,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Frequent Poster","user_id":2106,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":315,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Temperature issue of EV Inverter at peak operating point","id":3228,"title":"Temperature issue of EV Inverter at peak operating point","slug":"temperature-issue-of-ev-inverter-at-peak-operating-point","posts_count":31,"reply_count":25,"highest_post_number":31,"image_url":null,"created_at":"2025-05-29T08:58:47.130Z","last_posted_at":"2025-06-30T19:07:59.173Z","bumped":true,"bumped_at":"2025-06-30T19:07:59.173Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"We are using MOSFET based air cooled Inverter for EV car. Maximum current rating is 425A. MOSFET allowed temp=100°C \nTotal MOSFETs=42. Total arms=6, Number of MOSFET in one arm=7 \nThe loss values are found out using Alta&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"visibility_reason_id":1,"tags":[{"id":26,"name":"thermal-management","slug":"thermal-management"}],"tags_descriptions":{},"views":585,"like_count":24,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":17,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":2051,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Recent Poster","user_id":13,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"“If you don’t control the energy, it will misbehave.”","id":3319,"title":"“If you don’t control the energy, it will misbehave.”","slug":"if-you-don-t-control-the-energy-it-will-misbehave","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/e11afe60233a4ca5ab4a327f5dc9628343c382fe_2_1024x570.jpeg","created_at":"2025-06-25T15:50:57.348Z","last_posted_at":"2025-06-25T15:50:57.430Z","bumped":true,"bumped_at":"2025-06-25T15:50:57.430Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"In this snippet from Trace Talks, legendary EMC expert Dan Beeker joins Amit Bahl to break down one of the most misunderstood aspects of electromagnetic compatibility: \nIt’s not the switching output that causes the pro&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":5,"name":"emc","slug":"emc"},{"id":199,"name":"trace-talks","slug":"trace-talks"},{"id":242,"name":"podcast","slug":"podcast"}],"tags_descriptions":{},"views":50,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":22,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Is It Standard to Route Power Traces Before Pouring Planes?","id":3284,"title":"Is It Standard to Route Power Traces Before Pouring Planes?","slug":"is-it-standard-to-route-power-traces-before-pouring-planes","posts_count":2,"reply_count":0,"highest_post_number":2,"image_url":"https://global.discourse-cdn.com/sierraconnect/original/1X/f041334a05f6db159f8b4bafbb0ff8a18729e72a.png","created_at":"2025-06-17T09:40:57.650Z","last_posted_at":"2025-06-17T12:34:02.840Z","bumped":true,"bumped_at":"2025-06-17T12:34:02.840Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Hi community, \nI’m designing a multilayer PCB for the first time and currently working on the power distribution layout. \nWhile watching a YouTube PCB design tutorial, I noticed the designer first routed a trace for a po&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":47,"name":"power-integrity","slug":"power-integrity"}],"tags_descriptions":{},"views":124,"like_count":4,"has_summary":false,"last_poster_username":"timothy.phillips","category_id":20,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":1769,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":59,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"How do you approach EMI?","id":3244,"title":"How do you approach EMI?","slug":"how-do-you-approach-emi","posts_count":9,"reply_count":4,"highest_post_number":9,"image_url":null,"created_at":"2025-06-04T17:18:07.758Z","last_posted_at":"2025-06-16T03:14:53.578Z","bumped":true,"bumped_at":"2025-06-16T03:14:53.578Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Hi everyone. \nSierra has been partnering with a lot of wonderful EMI and EMC experts lately so I figured I’d start a discussion on the topic of EMI. \nI’ve been reviewing a few recent designs and it reminded me how much o&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":45,"name":"emi","slug":"emi"}],"tags_descriptions":{},"views":238,"like_count":13,"has_summary":false,"last_poster_username":"JimJJewett","category_id":22,"op_like_count":2,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":48,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Frequent Poster","user_id":1806,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Frequent Poster","user_id":495,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Recent Poster","user_id":603,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":526,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"WEBINAR HIGHLIGHT: Crazy-dense boards, real-world problems: Power integrity under pressure by Steve Sandler","id":3239,"title":"WEBINAR HIGHLIGHT: Crazy-dense boards, real-world problems: Power integrity under pressure by Steve Sandler","slug":"webinar-highlight-crazy-dense-boards-real-world-problems-power-integrity-under-pressure-by-steve-sandler","posts_count":2,"reply_count":0,"highest_post_number":2,"image_url":null,"created_at":"2025-06-03T16:21:21.229Z","last_posted_at":"2025-06-05T12:03:26.635Z","bumped":true,"bumped_at":"2025-06-05T12:03:26.635Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"In this webinar snippet, Steve Sandler breaks down the real-world PI challenges behind some of today’s most complex PCBs—like Intel’s Gaudi. From ultra-dense layouts and limited test access to high current demands and&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":47,"name":"power-integrity","slug":"power-integrity"},{"id":214,"name":"steve-sandler","slug":"steve-sandler"}],"tags_descriptions":{},"views":71,"like_count":2,"has_summary":false,"last_poster_username":"marko.duksi","category_id":20,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":1,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":1806,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Designing a Power Plane on an Internal Layer with 0.5 oz Copper","id":3241,"title":"Designing a Power Plane on an Internal Layer with 0.5 oz Copper","slug":"designing-a-power-plane-on-an-internal-layer-with-0-5-oz-copper","posts_count":5,"reply_count":2,"highest_post_number":5,"image_url":"https://global.discourse-cdn.com/sierraconnect/original/1X/17ec1df9c5cbfd8a1b42193eff38f3534a1f387b.png","created_at":"2025-06-03T17:45:39.568Z","last_posted_at":"2025-06-04T16:25:40.432Z","bumped":true,"bumped_at":"2025-06-04T16:25:40.432Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"I’m working on designing the power plane in Layer 5 of a multi-layer PCB. According to the datasheet, VDD_DDR and VDDCORE should be solid power planes. I’m currently planning to route multiple power rails in this single &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[],"tags_descriptions":{},"views":153,"like_count":5,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":20,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":1769,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Recent Poster","user_id":48,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"How Do You Estimate Power When Datasheets Lack Current Specs?","id":3189,"title":"How Do You Estimate Power When Datasheets Lack Current Specs?","slug":"how-do-you-estimate-power-when-datasheets-lack-current-specs","posts_count":6,"reply_count":4,"highest_post_number":6,"image_url":"https://global.discourse-cdn.com/sierraconnect/original/1X/474e621cfcdf71dbf189f5b19829c3e1e0da5334.png","created_at":"2025-05-15T14:32:00.674Z","last_posted_at":"2025-05-30T16:57:05.806Z","bumped":true,"bumped_at":"2025-05-30T16:57:05.806Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Hi everyone, \nI’m working on a custom board’s power budget but struggling because key components (RTL8211F-CG PHY and STM32MP157FAC1) don’t clearly specify load currents in their datasheets. Without these numbers, I’m un&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[],"tags_descriptions":{},"views":163,"like_count":6,"has_summary":false,"last_poster_username":"abhishek","category_id":17,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":1769,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":13,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"EMI: Pinning down the noise issues","id":3190,"title":"EMI: Pinning down the noise issues","slug":"emi-pinning-down-the-noise-issues","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/97b11fe7b0ccdc88132c26c6032fccc71e5dbfa7_2_1024x574.jpeg","created_at":"2025-05-15T16:24:43.684Z","last_posted_at":"2025-05-15T16:24:43.784Z","bumped":true,"bumped_at":"2025-05-15T16:24:43.784Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"&quot;So figuring out where the problem was, finally, one of us was under the vehicle, and we’re just going step by step every single box that was hanging off the high voltage system. And there’s also this water heater. A l&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":45,"name":"emi","slug":"emi"},{"id":5,"name":"emc","slug":"emc"},{"id":211,"name":"karen-burnham","slug":"karen-burnham"},{"id":199,"name":"trace-talks","slug":"trace-talks"}],"tags_descriptions":{},"views":54,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":22,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Designing Transmission Lines with Controlled Impedance in High-Speed PCB Layouts","id":3180,"title":"Designing Transmission Lines with Controlled Impedance in High-Speed PCB Layouts","slug":"designing-transmission-lines-with-controlled-impedance-in-high-speed-pcb-layouts","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-05-14T16:40:10.229Z","last_posted_at":"2025-05-14T16:40:10.328Z","bumped":true,"bumped_at":"2025-05-14T16:40:10.328Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Originally published at:\t\t\thttps://www.protoexpress.com/blog/designing-transmission-lines-with-controlled-impedance-high-speed-pcb-layouts/ \n Imagine you’re designing PCB transmission lines for a high-speed application. &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":75,"name":"signal-integrity","slug":"signal-integrity"},{"id":241,"name":"pcb-transmisison-lin","slug":"pcb-transmisison-lin"}],"tags_descriptions":{},"views":117,"like_count":1,"has_summary":false,"last_poster_username":"PoulomiG","category_id":18,"op_like_count":1,"pinned_globally":false,"featured_link":"https://www.protoexpress.com/blog/designing-transmission-lines-with-controlled-impedance-high-speed-pcb-layouts/","featured_link_root_domain":"protoexpress.com","has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":53,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Decoupling Capacitor Placement Rules Every PCB Designer Should Know","id":3118,"title":"Decoupling Capacitor Placement Rules Every PCB Designer Should Know","slug":"decoupling-capacitor-placement-rules-every-pcb-designer-should-know","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-04-24T14:23:38.424Z","last_posted_at":"2025-04-24T14:23:38.504Z","bumped":true,"bumped_at":"2025-04-24T14:23:38.504Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Originally published at:\t\t\thttps://www.protoexpress.com/blog/decoupling-capacitor-placement-guidelines-pcb-design/ \n Decoupling is a way of isolating signal components from composite signals based on frequency. Therefore&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":18,"name":"decoupling-capacitor","slug":"decoupling-capacitor"}],"tags_descriptions":{},"views":79,"like_count":1,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":20,"op_like_count":1,"pinned_globally":false,"featured_link":"https://www.protoexpress.com/blog/decoupling-capacitor-placement-guidelines-pcb-design/","featured_link_root_domain":"protoexpress.com","has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Analyzing Eye Diagrams for Signal Integrity in High-Speed PCBs","id":3111,"title":"Analyzing Eye Diagrams for Signal Integrity in High-Speed PCBs","slug":"analyzing-eye-diagrams-for-signal-integrity-in-high-speed-pcbs","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-04-22T16:24:38.319Z","last_posted_at":"2025-04-22T16:24:38.401Z","bumped":true,"bumped_at":"2025-04-22T16:24:38.401Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Originally published at:\t\t\thttps://www.protoexpress.com/blog/analyzing-eye-diagrams-for-signal-integrity-high-speed-pcbs/ \n An eye diagram is one of the most effective methods for analyzing the signal integrity of your P&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":237,"name":"signal-integrity-ana","slug":"signal-integrity-ana"},{"id":236,"name":"eye-diagram","slug":"eye-diagram"}],"tags_descriptions":{},"views":188,"like_count":0,"has_summary":false,"last_poster_username":"Pooja_Mitra","category_id":19,"op_like_count":0,"pinned_globally":false,"featured_link":"https://www.protoexpress.com/blog/analyzing-eye-diagrams-for-signal-integrity-high-speed-pcbs/","featured_link_root_domain":"protoexpress.com","has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":47,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"WEBINAR HIGHLIGHT: Manufacturing Stacked Vias","id":3110,"title":"WEBINAR HIGHLIGHT: Manufacturing Stacked Vias","slug":"webinar-highlight-manufacturing-stacked-vias","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-04-21T16:34:31.722Z","last_posted_at":"2025-04-21T16:34:31.813Z","bumped":true,"bumped_at":"2025-04-21T16:34:31.813Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"https://protoexpress.wistia.com/medias/x5vo5u1tfc \nThis part of our webinar on via design and manufacturing highlighted important considerations when choosing between stacked and staggered vias for high-density interconn&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":40,"name":"via","slug":"via"},{"id":11,"name":"hdi","slug":"hdi"}],"tags_descriptions":{},"views":57,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":21,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"TRUE OR FALSE: EMC Edition","id":3094,"title":"TRUE OR FALSE: EMC Edition","slug":"true-or-false-emc-edition","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/ace502a9d4b7647489a14142441b71378302b742_2_1024x569.jpeg","created_at":"2025-04-17T16:20:45.492Z","last_posted_at":"2025-04-17T16:20:45.589Z","bumped":true,"bumped_at":"2025-04-17T16:20:45.589Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Q: Components with high current draw are less likely to generate EMC issues. True or false? \nA: False. \n\nThat should be obvious—high current can often correlate with more EMC issues. \n\n\nQ: Can reducing trace lengths he&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":5,"name":"emc","slug":"emc"}],"tags_descriptions":{},"views":52,"like_count":1,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":22,"op_like_count":1,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"“So what are the guidelines for a good grounding system?” “In two minutes?”","id":3047,"title":"“So what are the guidelines for a good grounding system?” “In two minutes?”","slug":"so-what-are-the-guidelines-for-a-good-grounding-system-in-two-minutes","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/1146d21a41c5fc6a4c2e066ced5e0d160f623850_2_1024x565.jpeg","created_at":"2025-04-03T16:09:33.119Z","last_posted_at":"2025-04-03T16:09:33.194Z","bumped":true,"bumped_at":"2025-04-03T16:09:33.194Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Ignacio de Mendizábal discussed the fundamentals of grounding for high-speed PCB design, emphasizing the importance of understanding whether a system is AC, DC, analog, digital, or mixed-signal. He referenced Daniel Be&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":45,"name":"emi","slug":"emi"},{"id":5,"name":"emc","slug":"emc"},{"id":231,"name":"grounding","slug":"grounding"}],"tags_descriptions":{},"views":56,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":22,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Techniques to Measure and Avoid Jitter in PCBs","id":2996,"title":"Techniques to Measure and Avoid Jitter in PCBs","slug":"techniques-to-measure-and-avoid-jitter-in-pcbs","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-03-17T11:38:19.613Z","last_posted_at":"2025-03-17T11:38:19.691Z","bumped":true,"bumped_at":"2025-03-17T11:38:19.691Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Originally published at:\t\t\thttps://www.protoexpress.com/blog/techniques-to-measure-and-avoid-jitter-in-pcbs/ \n A signal’s deflection from its ideal rising and falling edges is called a jitter in PCB. The jitter in clock &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":227,"name":"jitter-in-pcbs","slug":"jitter-in-pcbs"}],"tags_descriptions":{},"views":83,"like_count":0,"has_summary":false,"last_poster_username":"PoulomiG","category_id":19,"op_like_count":0,"pinned_globally":false,"featured_link":"https://www.protoexpress.com/blog/techniques-to-measure-and-avoid-jitter-in-pcbs/","featured_link_root_domain":"protoexpress.com","has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":53,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"OPEN DISCUSSION: How do you optimize PCB stack-up for signal integrity, especially in high-speed or RF designs?","id":2952,"title":"OPEN DISCUSSION: How do you optimize PCB stack-up for signal integrity, especially in high-speed or RF designs?","slug":"open-discussion-how-do-you-optimize-pcb-stack-up-for-signal-integrity-especially-in-high-speed-or-rf-designs","posts_count":5,"reply_count":0,"highest_post_number":5,"image_url":null,"created_at":"2025-02-26T18:17:26.301Z","last_posted_at":"2025-03-04T17:12:00.399Z","bumped":true,"bumped_at":"2025-03-04T17:12:00.399Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Stack-up plays a critical role in managing impedance, minimizing crosstalk, and reducing signal loss. Do you prioritize layer arrangement, dielectric selection, or reference plane placement? Share your strategies, challe&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":75,"name":"signal-integrity","slug":"signal-integrity"},{"id":53,"name":"stack-up","slug":"stack-up"}],"tags_descriptions":{},"views":213,"like_count":3,"has_summary":false,"last_poster_username":"Lieniner","category_id":19,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":null,"description":"Original Poster","user_id":1,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Frequent Poster","user_id":505,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Frequent Poster","user_id":495,"primary_group_id":null,"flair_group_id":null},{"extras":null,"description":"Recent Poster","user_id":500,"primary_group_id":null,"flair_group_id":null},{"extras":"latest","description":"Most Recent Poster","user_id":499,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Impact of vias in high-speed signal transmission","id":2923,"title":"Impact of vias in high-speed signal transmission","slug":"impact-of-vias-in-high-speed-signal-transmission","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-02-17T17:28:47.192Z","last_posted_at":"2025-02-17T17:28:47.267Z","bumped":true,"bumped_at":"2025-02-17T17:28:47.267Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Vias play a crucial role in high-speed signal transmission, but if not designed properly, they can introduce impedance mismatches, signal skew, and attenuation. Think of it like water flowing through pipes of varying &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":40,"name":"via","slug":"via"}],"tags_descriptions":{},"views":99,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":21,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"Shielding effectiveness by Karen Burnham","id":2878,"title":"Shielding effectiveness by Karen Burnham","slug":"shielding-effectiveness-by-karen-burnham","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":null,"created_at":"2025-02-03T16:55:36.720Z","last_posted_at":"2025-02-03T16:55:36.800Z","bumped":true,"bumped_at":"2025-02-03T16:55:36.800Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Effective shielding is essential for ensuring proper EMC performance, but measuring it correctly can be tricky. @karen.burnham recently highlighted critical concepts for measuring shielding effectiveness, offering pra&hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":45,"name":"emi","slug":"emi"},{"id":211,"name":"karen-burnham","slug":"karen-burnham"},{"id":160,"name":"shielding","slug":"shielding"}],"tags_descriptions":{},"views":51,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":22,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"&ldquo;There&rsquo;s this thing I call the EMC fire triangle.&rdquo; - Karen Burnham","id":2840,"title":"\"There's this thing I call the EMC fire triangle.\" - Karen Burnham","slug":"theres-this-thing-i-call-the-emc-fire-triangle-karen-burnham","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/optimized/1X/dd65fbfd907630e2975f6392aa8d7acc36a40ad5_2_1024x568.jpeg","created_at":"2025-01-23T16:54:53.679Z","last_posted_at":"2025-01-23T16:54:53.766Z","bumped":true,"bumped_at":"2025-01-23T16:54:53.766Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"&quot;So there’s a thing I call the EMC fire triangle, and that is, the idea that a lot of us learned as kids that to have a fire, you need three things. You need fuel and you need oxygen and you need a heat source. And if &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":5,"name":"emc","slug":"emc"}],"tags_descriptions":{},"views":80,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":22,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]},{"fancy_title":"How via impedance impacts signal integrity","id":2815,"title":"How via impedance impacts signal integrity","slug":"how-via-impedance-impacts-signal-integrity","posts_count":1,"reply_count":0,"highest_post_number":1,"image_url":"https://global.discourse-cdn.com/sierraconnect/original/1X/1b19c943a704c118a1ba50a5683d34824ca50c44.jpeg","created_at":"2025-01-16T17:38:45.076Z","last_posted_at":"2025-01-16T17:38:45.146Z","bumped":true,"bumped_at":"2025-01-16T17:38:45.146Z","archetype":"regular","unseen":false,"pinned":false,"unpinned":null,"excerpt":"Via impedance plays a critical role in signal integrity. When the via impedance doesn’t match the transmission line impedance, reflections can occur, with their magnitude depending on the difference at the transition &hellip;","visible":true,"closed":false,"archived":false,"bookmarked":null,"liked":null,"tags":[{"id":75,"name":"signal-integrity","slug":"signal-integrity"},{"id":40,"name":"via","slug":"via"},{"id":20,"name":"controlled-impedance","slug":"controlled-impedance"},{"id":132,"name":"impedance","slug":"impedance"}],"tags_descriptions":{},"views":93,"like_count":0,"has_summary":false,"last_poster_username":"lucy.sierracircuits","category_id":18,"op_like_count":0,"pinned_globally":false,"featured_link":null,"has_accepted_answer":false,"can_vote":false,"posters":[{"extras":"latest single","description":"Original Poster, Most Recent Poster","user_id":1,"primary_group_id":null,"flair_group_id":null}]}]}}